Regulators have been working with utilities companies to enact rigid standards to control the impact of SSL technology on the power grid (figure 1). The move to LED-based solid state lighting promises a significant reduction in the carbon footprint of the electrical power grid simply due to the dramatic reduction in real power consumption. However, if power factor is not managed, the grid will still need to be able to provide a much higher power level than is actually needed at the load, eliminating a significant portion of the benefits of moving to solid state lighting.

Figure 1. Regional Standards for Power Factor and Total Harmonic Distortio. For better resolution click here

Historically, incandescent bulbs have had near-perfect power factor. Therefore, solid state lighting is being held to a much higher PF standard compared to legacy AC/DC power supplies. In most cases, power supplies are free from any form of power factor regulation for supplies rated up to 75W. However, for solid state lighting, PF regulations typically kick in as low as 5W or below.

In order to effectively design an LED-based luminaire, designers need to understand power factor, the impact LED drivers have on it, and different techniques for integrating power factor correction cost-effectively in the LED driver design.

Understanding Power Factor

Power factor is a simple, unit-less ratio of real power to apparent power. Real power is the power used at the load measured in kilowatts (kW). Apparent power is a measurement of power in volt-amps (VA) that the grid supplies to a system load. In a highly reactive system, the current and voltage, both angular quantities, can be highly out of phase with each other. This results in the power grid needing to supply a much larger reactive power to be able to supply the actual real power at any given time.

The ratio of the reactive power to the real power is called power factor (PF). This basically means that for an equivalent real power consumed by a highly reactive load, for example 5W, the actual current that the grid needs to supply to the load in order to provide the real power has to be higher than the real power by the power factor ratio. For the previous 5W example, for a load with a PF of 0.5, the grid needs to provide 2x the current actually required by the load at any given time. This adverse impact on the power grid does not apply to incandescent lighting, which is purely resistive and has a unity power factor.

Figure 2. Power Factor – Ratio of Real Power (kW) to Reactive Power (kVA)

Solid state lighting that incorporates power factor correction can reduce the impact of the change from incandescent to LED based lighting by increasing the power factor to near unity by adding circuitry to the LED driver that corrects for the reactive input impedance.

LED Drivers and Power Factor Correction

LEDs have a non-linear impedance as do their drivers, causing the power factor to be inherently low. In order to combat this, the driver needs to compensate for power factor to increase that ratio as close to 1 as possible. When you take into consideration one LED lamp and its impact on the overall PF for an industrial warehouse or shopping mall, it is relatively insignificant, but the sum of all the lighting elements in a large commercial space can significantly impact the overall power factor and correction for either each individual bulb or for the ballasts that drive those bulbs needs to be implemented.

Both active and passive methods exist for PFC. Passive PFC solutions typically consist of passive input filers and offer some cost benefits, but since passive PFC optimizes for a specific input voltage and current condition, when those conditions change, the power factor also decreases. In the case of dimmable luminaires, passive PFC is not acceptable as the power factor will vary broadly across the full operating brightness range of the bulb. Active PFC needs to be incorporated to adequately maintain high PFC across load and line conditions.

With active PFC, there are approaches that use the main power conversion stage to compensate for the power factor (single-stage) and approaches that use an independent pre-regulator stage to provide the PFC (two-stage) (figure 3). Each approach has its benefits; the most obvious is that with a single-stage approach, the cost to implement is minimized since part of the PFC work is done in the main power conversion stage. Determining which topology best suits the end applications requires a deeper analysis of each type of converter.

Figure 3. Single-Stage and Two-Stage PFC Architectures

With a single-stage LED driver, the main power stage converts the input voltage to a usable DC voltage and current for driving the LEDs. Since there is only one power stage, the driving of the main power stage needs to be managed to increase the PF close to unity. Since the measure of power factor depends upon how linear the input of the driver looks to the mains input voltage, the modulation topology determines what the input impedance of the converter looks like to the mains.

The best approach to maximize power factor is to use a constant-on time approach, which effectively creates a voltage-controlled current source, or a highly resistive–looking input impedance. The peak current through the primary side of the transformer is directly proportional to the on-time of the primary drive. This inherently has a high PF, near 1. While the constant on-time architecture offers the benefit of high power factor, the trade-offs are often times unacceptable. Normally operated in DCM mode, the peak currents are very high and have two major consequences, high stress on the passive components and high current ripple on the LEDs. The high stress on the input capacitors can degrade the lifetime of these key components and lead to reduced operating lifetime on the bulb. The excessive current ripple on the output reduces the quality of the light output by adding flicker to the light output as well as degrading efficiency and increasing self-heating due to the ripple current through the output capacitors.

Using a constant current mode operation instead of constant on-time alleviates the ripple current on the output and reduces the stress on the passive components in the circuit, but due to the inherently reactive nature of the input impedance, the power factor diminishes significantly.

Finding an alternative approach that combines high PF and low ripple current while minimizing the impact on the passive external components is key to finding the optimal low-cost solution in a single-stage LED driver.

The iW3626 (figure 4) shows an example of a single-stage, high PF LED driver that combines a high PF driver with the ability to minimize the output ripple. The technology to accomplish this resides in the core of digital engine that monitors input voltage and current along with the output conditions by monitoring the primary side of a power transformer. The digital core allows for modulating the drive to the main power transistor, in this instance a power bipolar junction transistor. The proprietary modulation technique in this example allows the end user to program the desired minimum power factor at 0.7, 0.8 or 0.9, or no power factor at all. Along with the minimum power factor comes a corresponding output ripple. This flexibility allows the designer to optimize the circuit for either output ripple (with no PFC) or for PF (with moderate output ripple), or for a balanced, high PF and low output ripple design.

Figure 4. iW3626 – Single-Stage, Non-Dimmable PFC LED Driver

An additional LED driver characteristic important in solid state lighting, and also regulated by the international lighting standards shown in figure 1, is total harmonic distortion (THD). As a general rule, when THD is low, power factor tends to be high (>0.9). But, with single-stage conversion technology, normally there is a trade-off between output ripple, THD and PF. The iW3626 uniquely combines low output ripple and high PF with THD at an acceptable level for most applications. THD is of particular interest in the US market, while in Europe, the IEC61000-3-2 establishes harmonic requirements for power supplies. When the end application demands low THD, high PF and low output ripple, two-stage approaches fit the bill.

The main difference between single-stage and two-stage approaches is the obvious addition of a second conversion stage. The additional conversion stage does the power factor correction while minimizing the total harmonic distortion. Not only does the initial conversion stage remove the line frequency from the main output voltage, removing flicker from the light output, it also adds flexibility for integrating dimming technology and reduces in-rush current which benefits the passive components on the input. Two-stage approaches can use either a boost converter or a simple chopping circuit for the initial stage. The full boost converter offers higher efficiency, higher PFC and lower THD across a broader line voltage range compared to a simple chopper circuit.

The iW3630 is an example of a two-stage LED driver for solid-state lighting applications that require high PF (>0.95), low THD (<15%) and low output ripple (figure 5). The first stage is a full boost converter operated in a constant on time architecture to optimize power factor and minimize THD. This stage converts the mains voltage into an intermediate voltage, decoupling the output from the mains voltage and frequency.

The second, main power conversion stage then converts the intermediate voltage into usable DC voltage and current for driving the LEDs. This can be an isolated or non-isolated stage depending upon the needs of the end application. With the iW3630, whether the application is isolated or not, there is no need for an optical feedback device because the main feedback is derived from the primary side of the transformer, using iWatt’s PrimAccurateTM technology.

Figure 5. iW3630 Two-Stage, PFC Controller with 0V to 10V Dimming Interface for Commercial SSL Applications

Conclusion

With regulations dictating power factor requirements for solid state lighting, designers need to incorporate power factor correction circuits into the driver design. A clear understanding of the end requirements based on the intended application of the luminaire determines the type of power factor correction that needs to be implemented. Whether single-stage, cost-driven solutions for residential lighting, or two-stage performance-driven solutions for commercial and industrial applications, the driver technology now exists to enable a brighter, greener future.

References:

1. Fact Sheet: Light’s Labour’s Lost. International Energy Agency (IEA). https://www.iea.org/publications/freepublications/publication/name,3682,en.html

About the Author:

Hubie Notohamiprodjo is the director of marketing for Solid State Lighting Products at iWatt Inc. He has over 28 years of experience in the lighting industry, along with extensive global experience in the power management market. Prior to iWatt, Hubie served as Director of Marketing for AC-DC/Lighting products at Monolithic Power Systems and General Manager of Marvel Semiconductor’s Power Management Division. He also held power management positions at Siemens, Motorola and Micrel Semiconductor and was the founder of energy-saving lighting systems company, Lumina International. Hubie earned his BSc degree in Electrical Engineering from the University of Nebraska-Lincoln and holds more than 21 patents.

If you enjoyed this article, you will like the following ones: don't miss them by subscribing to :    eeNews on Google News

Share:

Linked Articles
10s