Programmable linear actuator with RS-485 communication protocol

Programmable linear actuator with RS-485 communication protocol

New Products |
By eeNews Europe



The IDEA platform also has added the capability of communication using an RS-485 data protocol, overcoming the limitations of other drive communication methods. The main advantage for using the RS-485 protocol, especially for industrial equipment such as stepper drives, industrial motor drives, and servo systems, is the ability for long data transmissions that exhibit excellent immunity to electrical noise. The IDEA devices can communicate over a 1000-foot network without the need for termination resistors and to reach up to 256 addressable device nodes. An industrial controller can send commands to all the drives at once or control each drive separately when assigned a unique identifier, a number between 0 and 255. Among the hardware features of the IDEA Drive platform are programmable current control, a single supply voltage of 12 to 48 VDC, 2.6Arms (3.68A peak) max rated current per phase, and 8 opto-isolated general purpose I/O. The inputs are rated for 5 to 24 VDC, 4mA max per input. The outputs are open collector, 5 to 24 VDC, 200mA maximum per output.

Visit Haydon Kerk Motion Solutions at www.HaydonKerk.com

 