
Reconfigurable mask enables lensless medical imaging
The team at Penn State developed the medical imaging technique that does not require a lens but uses reconfigurable particle-based masks instead to take multiple shots of an object.
The lensless camera uses electric-field directed self-assembling mask technology that is ideal for use in lower-cost and faster disease diagnosis. It could also find use in the enhancement of optical microscopy and could enable thinner cellphone technology.
The lensless camera is based on a mask of microscopic gold wires placed near the object that will be imaged. The mask scatters the light reflected off the object and an image sensor collects the light. An electric current rearranges the particles in the mask, producing a new mask with every iteration, and the system records each new image. The multiple light captures are then computationally reconstructed into the original object image, resulting in highly improved resolution and quality.
“We are not the only group to do lens-free imaging,” explained Jennifer Miller, a doctoral candidate in chemistry and a first author on a paper recently published online in ACS Nano. “What is different about our work is that typically you would need to make multiple masks and physically move them around to get multiple images. This becomes bulky and expensive and negates some of the simplicity that is the advantage of lens-free imaging.”
In typical microscopy, there exists a trade-off between the field of view and the power of the resolution, so a 10x field is wider than a100x field. By using a lens-free imaging technology, it is possible to combine a wide field of view with high magnification for lower-cost images and faster diagnosis of disease. This could be especially useful in developing countries where high-end microscopes are not available.

“Traditional masks are passive,” said co-first author Cheng-Yu Wang, doctoral candidate in electrical engineering. “We can add functionalization to our microwire, like polarization, selectivity and plasmonic effects, that make our imaging system more powerful.”
In the case of cellphones, one major contributor to their bulk is due to the camera lens needing to be a certain distance to the detector. A lensless camera could help minimize the space requirement. Likewise, a lens-free system added to a cellphone could turn the cellphone into a low-power microscope.
Along with Miller and Yang, senior authors on the ACS Nano paper, “Particle-based reconfigurable scattering masks for lensless imaging,” are Christine Keating, distinguished professor of chemistry, and Zhiwen Liu, professor of electrical engineering.
Research paper: https://dx.doi.org/10.1021/acsnano.0c04490
Related articles
- Fast algorithms enable 3D holograms without GPUs
- Smartphone image sensor targtes mirrorless, DSLR cameras
- First 5G smartphone with under-display camera
- Neural network and simple ToF sensor can generate 3D images
Other articles on eeNews Europe
- Why the Tesla Battery Day matters for Europe
- World first with multiple Covid-19 test machine
- First Bizen quantum tunnelling transistors launched
- ARM splits its Neoverse datacentre server chip designs